Intel SSD (X25-M) の S.M.A.R.T.
SSD Enhanced SMART ATA feature set
Intel® X18-M/X25-M SATA Solid State Drive
SMART attribute の 232 と 233 が SSD 関連かなぁ。ドキュメントがない ><
$ sudo /usr/sbin/smartctl -d ata -a /dev/sdb smartctl version 5.36 [x86_64-redhat-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: INTEL SSDSA2MH080G1GC Serial Number: CVEM835400A7080DGN Firmware Version: 045C8610 User Capacity: 80,026,361,856 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1 Local Time is: Wed Oct 29 17:22:58 2008 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 32) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: ( 1) seconds. Offline data collection capabilities: (0x75) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 5) minutes. Conveyance self-test routine recommended polling time: ( 1) minutes. SMART Attributes Data Structure revision number: 5 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 3 Spin_Up_Time 0x0000 100 000 000 Old_age Offline In_the_past 0 4 Start_Stop_Count 0x0000 100 000 000 Old_age Offline In_the_past 0 5 Reallocated_Sector_Ct 0x0002 100 100 000 Old_age Always - 0 9 Power_On_Hours 0x0002 100 100 000 Old_age Always - 4 12 Power_Cycle_Count 0x0002 100 100 000 Old_age Always - 3 192 Power-Off_Retract_Count 0x0002 100 100 000 Old_age Always - 3 232 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 0 233 Unknown_Attribute 0x0002 099 099 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1 SMART Selective self-test log data structure revision number 0 Warning: ATA Specification requires selective self-test log data structure revision number = 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.